Model: IFP4M
Wide range power supply
History records of 100,000 events
CAN/Fiber Networking, Panel grouping
7-inch Touch Screen 800 x 480
Model: GST-M200
Single loop fire alarm control panel
Optional 2 loops with additional loop card
Notification Appliance Circuits (NAC)
Programmable from panel
Model: GST-MNA2C
Capacitive Touch screen
Class A CAN network interface
History file 100,000 events capacity
User programmable password
Model: GST-MNA2F
Fiber network interface
History file 100,000 events capacity
Capacitive Touch screen
User programmable password
Model: DI-M9101
Address can be set in field
Fault self-diagnostic
Reed switch testing
Polling LED can be set to close
Model: DI-M9102
Fault self-diagnostic
A magnet test available
Polling LED can be set to OFF
Built-in microprocessor stores
Model: DI-M9103
Address can be set in field.
Fault self-diagnostic.
Reed switch testing.
Polling LED can be set to OFF
Model: DI-M9204
Plug-in structure
Alarm by pressing
Electronically addressed
Wiring before termination
Model: DI-M9204F
Plug-in structure
Alarm by pressing
Electronically addressed
Wiring before termination
Model: DC-M9204
Alarming by pressing
Plug-in structure
Semi-flush or surface mount installation
Model: GST-MNA2F
Alarming by pressing
Plug-in structure
Semi-flush or surface mount installation
Model: DC-M9503
Din-Rail mount, Surface mount
LED status indication
Support Class A SLC loop
UL Approved
Model: DI-M9319
Input port cable monitoring with 4.7KΩ EOLR
Two indicators for fire and fault.
LED status indication
Model: DI-M9300
Input port monitored with 4.7KΩ EOLR.
Normally open or closed contact acceptable
LED status indication
Model: DI-M9301
Input port monitored with 4.7KΩ EOLR.
Normally open or closed contact acceptable
LED status indication
Model: C-M9503
Polarity-sensitive external connections.
Delayed power-up to output end devices
Avoids strong transient..
Model: DI-M9305
Output port monitored with 47KΩ EOLR.
Electronically addressed
LED status indication
Model: DC-M9504
Technical Specifications
Operating Voltage: 24V
Standby Current ≤0.15mA
Action Current≤ 2mA
Model: DC-M9410
Small in size
Can be installed into single-gang box
Compatible electrical boxes
Model: DC-M9101
Reed switch testing.
Remote indicator output available.
2 levels smoke sensitivities programmable
Relative Humidity: 95%, non-condensing
Model: DC-M9102
Providing for connections to remote indicators
A magnet test available
Operating voltage: 24VDC(16VDC~28VDC)
Relative Humidity: 95%.
Model: DC-M9103
Reed switch testing
Output terminal for remote indicator available
Rate of rise and fixed temperature
Fixed temperature programmable
Model: DC-M9413
Features & enhanced synchronization circuit
Field-configurable option
Switch for desired candela output
Model: DC-M9414
Temporal or steady sounder output
High dB or low dB output
Designed for indoor use.
Operation Voltage 24 VDC
Model: DC-M9415
Temporal or steady sounder output
High dB or low dB output
Designed for indoor use.
Operation Voltage 24 VDC
Model: DC-M9416
Features & enhanced synchronization circuit
Field-configurable option
Switch for desired candela output
Model: GST-MP
Panel of GST voice evacuation system
provides interface to the FACP
2 models of basic master panels
Model: GST-DP
Communications: RS-485 Standard
Primary Supply: 220VAC
Electrical Ratings: All Circuits @ 24VDC
End of Line Resister: 0kΩ
Model: P-9910B
Hand held unit, portable tool
Convenience operation
Quadruple digit alphanumeric LCD
Low battery indication
Model: C-9314P
LED indication available.
Built-in current-limiting resistor.
Operating Voltage 2.0VDC - 3.0VDC
Operating Temperature: