GST LPCB Approved Fire Alarm System equipment are as below
Fire Alarm Control Panel

Fire Alarm Control Panel
Model: GST-IFP8
Day and Night Mode
Enable and Disable function
40 x15 lines LCD Display
Duplicate Address Checking

Fire Alarm Control Panel
Model: GST200N
30 logical configurable zones
PAS and Acknowledge Function
Dirty Detector Reporting
Graphical LCD Display

Fire Alarm Control Panel
Model: GST100
Single loop addressable panel
Can connect up to 128 addressable devices
Self configurable via panel keyboard
Graphical LCD Display
LPCB Approved Detectors

Intelligent Multi Detector
Model: DI-9101E
Electrically addressed
Self-diagnostic
Possible to switch off pulling LED

Photoelectric Smoke Detector
Model: DI-9102E
Three sensitivity levels
Electronically addressed
Aesthetically pleasing Low profile design
Dust / corrosion / humidity resistant

Heat Detector
Model: DI-9103E
Electrically addressed
3 classes programmable
LED for 360° vision

Ultraviolet Flame Detector
Model: I-9104
Three sensitivity levels
Electronically addressed
Aesthetically pleasing Low profile design
Dust / corrosion / humidity resistant

Reflective Beam Detector
Model: I-9105R
Range 8 -100 Meters
Maximum width: 14m
Two sensitivity levels
Ideal for Atriums, Warehouses etc.

Addressable Gas Detector
Model: I-9602LW-NG/LPG/CG
Available for LPG, Natural Gas and Coal Gas
Built-in 2 relay contacts
Alarm, Fault, Power indication
Electronically addressed
LPCB Approved Digital Manual Call Point

Digital Manual Call Point
Model: DI-9204E
Advanced digital communication
Friendly installation and test
Surface mount, Semi-flush mount
Re-settable (non-breaking glass) via special key.
LPCB Approved Sounder Strobe

Addressable Souder Beacon
Model: I-9401
Electronically addressed
Plug-in construction
Standby Current 0.8mA, Alarm Current 6.0mA
Standby Current 10mA, Alarm Current 160mA

Addressable Sounder Base
Model: I-9402
Loop Powered
Electronically addressed
Standby Current≤ 1mA
Alarm Volume (SPL): 89dB @1 Meter

Intelligent Sounder Strobe
Model: I-9403
16 programmable alarm tones
Power saving mode or Normal mode
Electronically addressed
Comply with EN54-3

Intelligent Sounder
Model: I-9404
16 programmable alarm tones
Single or dual address programmable
loop powered or external 24VDC powering
Electronically addressed

Flashing Beacon Base
Model: I-9406
Sandwich structure
16 programmable tones
Three working modes
Electronically addressed

Addressable Beacon Base
Model: DI-9406
16 programmable tones
Electronically addressed
Technical Specifications
Tone 14 and Tone 16 are EN54-3 compliant
LPCB Approved Intelligent Modules

Address. Input Interface
Model: I-9300S
Electronically addressed
EOLR is used for cable monitoring
Possible monitoring NO or NC dry input
Operation Voltage: Loop 24VDC

Address. Output Interface
Model: I-9301S
Output cable checking
Electronically addressed
Standby Current: Loop≤ 1mA, Power≤1.5mA
Dimension: 50mm x 44mm x 17mm

Base Mount Isolator
Model: DC-9504E
LED status indicator
Remote indicator output
Compatible with DI series detector
Relative Humidity: 95% non condensing

Base Mount Isolator
Model: DI-9300E
Standard: EN 54-18:2005
Din-Rail mount or surface mount
LED status indication
loop Powered

Digital I/O Module
Model: DI-9301E
LED status indication
Din-Rail mount, Surface mount
Action Current≤ 0.7mA
Temperature: -10°C - +55°Cbr/>

Single Riser Output Module
Model: DI-9305E
Input port monitored
Din-Rail mount, Surface mount
Standard: EN 54-18:2005
Dimension: 85.3mm×78mm×33mm

Digital Zone Monitor Unit
DI-9319E
Monitoring power supply.
Two indicators for fire and fault.
Din-Rail mount or surface mount
Dimension: 85.3mm×78.0mm×33.0mm

Loop Isolator
Model: DC-9503E
Din-Rail mount, Surface mount
LED status indication
Standard: EN 54-17:2005
Dimension: 78mm×45.3mm×28.5mm

Passive Remote Indicator
Model: C-9314P
LED indication available
Built-in current-limiting resistor
Action current≤ 30mA
Dimensions: 64.5 x 64.5 x 31.4mm

Multi-Channel Interface
Model: DI-9309
Individual state LED for each input
Power supply monitored
2 dry contact outputs
Dimension: 200mm x 100mm x 20mm
LPCB Approved Repeater Panels

LCD Repeater Panel
Model: GST852RP
Back lit LCD displaying all fire information
Local sounder mute and scroll alarms buttons
Relative Humidity: 95%, non condensing
Dimension: 234mm x 104mm x 35mm

Graphic Repeater Panel
Model: GST8903
Up to 100 LED indication points
Graphical layout to project requirement
A3, A2 and A1 sizes
Relative Humidity: 95% non-condensing

Network Repeater Panel
Model: GST-NRP00
Provides remote control of system
Password protect access levels
Flush-mount or Surface-mount structure
Functional control of network panels
LPCB Approved Accessories and Tools

Hand Held Programmer
Model: P-9910B
Hand held unit, portable tool
Convenience operation
Programs all loop devices (1-242)
Low battery indication

Common Base
Model: DB-01, 01D, DZ-03, 03T, 03D
Suitable for DI-910xE Series Detectors
Suitable for DC-910xE series Detectors
Suitable for I-910x Series Detectors
Suitable for C-910xE series Detectors

Active End of Line Unit
Model: DP-9907, P-9907
Co-operate with DB-01D
Enabling Line Continuity
Co-operate with DZ-03D
Suitable for DC-910x, C-910x series Detectors
Conventional Fire Alarm Control Panel

Conv. Fire Alarm Control Panel
Model: GST101
Single zone conventional fire panel
Compact design
Suitable for Active line monitoring
Suitable for resistor end of line monitoring.

Conv. Fire Alarm Control Panel
Model: GST102A/104A/108A/116A
Pleasing color and fascia design
Simplified user operation
Day/night mode selected
Zone isolate control

Conventional Repeater Panel
Model: DGST-RP16
Compatible with GST102A/4A/8A/16A
Powered from FACP directly
Zonal Fire and general Fault indication
Dimension: 280mm x 110mm x 46mm
Conventional Detectors

Multi Detector
Model: DC-9101E
LED for 360° vision
Reed switch testing
Remote indicator output available

Smoke Detector
Model: DC-9102E Conventional Photoelectric Smoke Detector
Reed switch testing
Remote indicator output available
2 levels sensitivities programmable

Heat Detector
Model: DC-9103E
Featuring magnetic test
Remote indicator output available
Reed switch testing

Flame Detector
Model: C-9104
Detects the UV rays emitted by a flame
Aesthetically pleasing low profile design
Dust, damp and corrosion-proof
Detection Angle: 80°

Smoke Detector
Model: R6601
N/O contact output
Contacts closed and self-lock
Scattering technology
Operating Voltage: 12VDC

Heat Detector
Model: R6602
N/O contact output
Contacts closed and self-lock
Scattering technology
Operating Voltage: 12VDC

Smoke Detector
Model: S-9102R
N/O contact output
Contacts closed and self-lock
Scattering technology
Operating Voltage: 12VDC

Smoke Detector
Model: S-9102N
N/O contact output
Contacts closed and self-lock
Scattering technology
Operating Voltage: 12VDC
Conventional Sounder Strobe

Conven.Souder Strobe
Model: C-9401
Operating Voltage: 24VDC
Standby Current≤ 10mA
Alarm Current≤ 160mA
Temperature: -10℃ ~+50℃

Conven. Sounder Strobe
Model: C-9403
2 selectable tones
Optional deep base
Action Current≤ 35mA
Sounder Output≥ 95dB @ 1 Metre

Conventional Sounder
Model: C-9404
Compatible with GST102A/4A/8A/16A
Powered from FACP directly
Zonal Fire and general Fault indication