Fire sprinkler is fitted at the end of pipeline to spray water for extinguishing or suppressing the fire. An upright sprinkler is installed at the top with an upper water deflector, so water coming out of the orifice shoots upward. Upright sprinkler is suited for areas that are difficult to access, like beams, ducts, and buildings with exposed ceilings.

Fire sprinkler is fitted at the end of pipeline to spray water for extinguishing or suppressing the fire. A pendent sprinkler protrudes and hangs down from the ceiling. It comes with a water deflector at the bottom, so water coming out of the orifice shoots downward. Pendent sprinkle is widely used in office or home buildings.

Fire sprinkler is fitted at the end of pipeline to spray water for extinguishing or suppressing the fire. A sidewall sprinkler is installed on the wall along or under a beam with only half of a deflector, so water coming out of the orifice shoots horizontally. Sidewall sprinkler is designed to protect small rooms, hallways, and others where sprinkler pipes are running up walls but not in the ceiling.

Concealed sprinkler at standard and quick response is decorative sprinkler featuring a flat cover plate designed to conceal the sprinkler for aesthetical benefit. When exposed to heat from a fire, the cover plate falls away and the Deflector drops down to its operational position to work as similar pendent sprinkler.

Zone control valve is a combined unit of 4 parts: signal butterfly valve, water flow indicator, pressure gauge and test & drain valve. They are assembled on fire pipeline to separates the fire area into small distribution zone for indication and control. Because of fire sprinkler or test valve activation, the indicator detects water flow and transmits signal to control system. After fire suppression, butterfly valve gets signal and shut down the water flow for recovering the system.

Test & Drain Valve features single handle ball valve inspector's test with large & integral sight glass allowing for maximum visibility when operated of which compact and integrated form allow for installation in both horizontal and vertical orientations in a minimal occupation of space.

A waterflow switch is a device that detects movement of water in a pipe. For fire protection purposes, if water is flowing, there must be a fire. The Waterflow Switch is a mechanical-to-electrical Fire Alarm input device; it tells the fire alarm system that water is flowing in the sprinkler system.

The Alarm Check Valve serves as a check valve by trapping pressurized water above the clapper and preventing reverse flow from sprinkler piping. The valve is designed to initiate an alarm during a sustained flow of water (such as the flow required by an open sprinkler) by operating an optional water motor alarm and/or alarm pressure switch. The valve is made suitable for use on variable pressure water supplies by adding the optional retard chamber to the standard trim.

Sprinkler flexible hose, also known as flexible sprinkler connection or flexible sprinkler drop, is used in suspended ceiling for connecting fire sprinkler and branch pipeline.

Rosette Escutcheon is used to install with fire sprinklers together, and ensure it looks beautiful. 1- Body: Stainless Steel 2- Color: Brass, Chromed, White or others 3- Size: DN15 or DN2

Typically metallic piping is made of steel or iron, such as unfinished, black (lacquer) steel, carbon steel, stainless steel, galvanized steel, brass, and ductile iron. Iron based piping is subject to corrosion if used within a highly oxygenated water stream.

Pipe Fittings are Piping component that helps in Changes the direction of the flow such as elbows, tees. Changes the size of the pipe such as reducers, reducing tees. Connect different components such as couplings and stop the flows such as Caps. There are different types of pipe fitting used in piping